Can I Put A 100 Gal Across Floor Joists
But larger is not always better when builders are constructing a home or adding a room addition.
Can i put a 100 gal across floor joists. 20 years keeping tropical fish. In this case your joists are adequate to support a 30 psf live load and 10 psf dead load. Fiberglass insulation is usually the best option though handling fiberglass can be dangerous and it is not the most eco friendly option in some cases. This is what i found underneath the area where i am planning on putting the aquarium.
I do put it across the floor joists not perpendicular just to disperse the weight across more joists. Hey guys i m just wondering if a 100 125 gallon tank would be okay on the 2nd floor of a single family house because in about a year or so i m planning on buying a tank in that gallon range for my 1 year old res and ybs or cooter not really sure which species it really is and unfortunately i don t have a camera to take at least decent shots to put on the id section. If the floor is sagging the damaged joist and or a few neighboring joists may need to be jacked up slightly to straighten or raise the floor so the sister joist can be put into place. Common sense tells you that large floor joists can carry more load and spacing joists closer together also increases the load bearing capacity of a floor.
The extra two inches of vertical distance when a floor is framed with 2 x 10 joists rather than 2 x 12s can be quite important for example. Can my floor support a 150 gallon fish tank. The new sister joist is cut to the same length or slightly shorter as the old joist and is inserted into the joist cavity and snugged up against the old joist. Spread the weight across as many floor joists as possible keep it close to load bearing walls below it or the steel i beams that support the floor joists of your home has them.
I have a 100 gallon tank i ve kept on the second floor of several different apartments houses and i have never had a problem. The subfloor easily supports the 1000 psf in punching shear and carries the 250 lb weight to the floor joists. As with the 125 gallon tank there is much to consider before opting for such a large setup. The span table for a 30 psf live load 10psf dead load floor indicates a required fb value of 1 315 and a minimum e value of 1 800 000.
I d treat the safe the same way one would treat a king sized water bed or large 100 gallon aquarium. I mo ved into a house that has wooden floor and a basement underneath. Consulting a structural engineer would be a good idea. Fiberglass rolls can be placed between joists but the fiberglass itself will need to be cut to fit properly between joists.
The floor joists must be able to support the 250 lb man not the 1000 psf foot pressure. How can i find out if my wood floors on the main house can support a 100 gallon tank with a 55 gallon sump. Gaps between the insulation and the floor can. In the example the joists have a spacing of 16 inches and a span of 11 feet 2 inches.
The insulation should press right up against the floor between joists. My heel is only 1 2 inch diameter so that s a pressure of over.